Description
Omron H3CA-8H Solid State Timer, 120V, 0.1 s to 9990 hr, 3A, On-Delay
48 x 48 x 89 mm, 100/110/120 VAC, Time range 0.1 s to 9990 h (7 range), Output Time-limit contact: DPDT, 8-pin round socket
Rated supply voltage | 100 VAC 50/60 Hz 110 VAC 50/60 Hz 120 VAC 50/60 Hz |
---|---|
Time range | 0.1s to 9990h |
Input method | No-voltage input |
Output modes | A (Power ON delay) |
Control output | Time-limit contact: DPDT |
Display method | LCD |
External connection method | 8-pin round socket |
Rated supply voltage | 100 VAC 50/60 Hz 110 VAC 50/60 Hz 120 VAC 50/60 Hz |
---|---|
Operating voltage range | 85% to 110% of rated supply voltage |
Power consumption | 10VA / 1W |
Time ranges(Number of ranges) | 7 |
Time ranges | 0.1 s to 99.9 s / 1 s to 999 s / 0.1 min to 99.9 min / 1 min to 999 min / 0.1 h to 99.9 h / 1 h to 999 h / 10 h to 9990 h |
Select method | Thumbwheel Switch |
Input method | No-voltage input |
Output modes | A (Power ON delay) |
Control output (Contact output) | Type: Time-limit contact: DPDT Switching capacities (Resistive load): 3 A at 250 VAC Minimum applicable load: 10 mA at 5 VDC (failure level: P Reference value) |
Reset system | Self-reset |
Power reset | Reset time: 0.1 s max. |
Display method | LCD |
Digit | 3 digit |
Ambient temperature | Operating: -10 to 55 ℃ |
Ambient humidity | Operating: 35 to 85%RH |
Accuracy of operating time | ±0.3% ±0.05 s (The values are based on the set value.) |
Setting error | ±0.5% ±0.05 s (The values are based on the set value.) |
Influence of voltage | ±0.3% ±0.05 s (The values are based on the set value.) |
Influence of temperature | ±0.3% ±0.05 s (The values are based on the set value.) |
Insulation resistance | 100 MΩ min. (at 500 VDC) |
Dielectric strength | Between current carrying metal parts and non-current carrying metal parts: 2000 Between control output terminals and operating circuit: 2000 Between non-continuous contacts: 1000 |
Impulse withstand voltage | 5 kV |
Vibration resistance (Destruction) | 10 to 55 Hz, 0.75 mm single amplitude each in 3 directions for 1 hour |
Vibration resistance (Malfunction) | 10 to 55 Hz, 0.5-mm single amplitude each in 3 directions for 10 min |
Shock resistance (Destruction) | 1,000 m/s**2, 3 times each in 6 directions |
Shock resistance (Malfunction) | 100 m/s**2, 3 times each in 6 directions |
Mechanical life | 10 million operations min. (under no load at 1,800 operations/h) |
Electrical life | 100,000 operations min. (3 A at 250 VAC resistive load at 1800 operations/h) |
Degree of protection | Panel surface: IP40 |
Mounting method | Flush mounting / Surface mounting |
External connection method | 8-pin round socket |
Accessory (sold separately) | Y92A-48D: Soft Cover Y92A-48B: Hard Cover Y92F-30: Flush mounting adapter Y92F-70: Flush mounting adapter Y92F-71: Flush mounting adapter |
Weight | 約110g |